All MIBs › WIENER-CRATE-MIB › outputStatus
outputStatus
Module: WIENER-CRATE-MIB
OID (symbolic): WIENER-CRATE-MIB::outputStatus
OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.4
Node type: OBJECT-TYPE
Type: Bits
Access: read-only
Description: A bit string which shows the status (health and operating conditions) of one output channel. If a bit is set (1), the explanation is satisfied: outputOn (0), output channel is on outputInhibit(1), external (hardware-)inhibit of the output channel outputFailureMinSenseVoltage (2) Supervision limit hurt: Sense voltage is too low outputFailureMaxSenseVoltage (3), Supervision limit hurt: Sense voltage is too high outputFailureMaxTerminalVoltage (4), Supervision limit hurt: Terminal voltage is too high outputFailureMaxCurrent (5), Supervision limit hurt: Current is too high outputFailureMaxTemperature (6), Supervision limit hurt: Heat sink temperature is too high outputFailureMaxPower (7), Supervision limit hurt: Output power is too high outputFailureTimeout (9), Communication timeout between output channel and main control outputCurrentLimited (10), Current limiting is active (constant current mode) outputRampUp (11), Output voltage is increasing (e.g. after switch on) outputRampDown (12), Output voltage is decreasing (e.g. after switch off) outputEnableKill (13), EnableKill is active outputEmergencyOff (14), EmergencyOff event is active outputAdjusting (15), Fine adjustment is working outputConstantVoltage (16), Voltage control (constant voltage mode) outputLowCurrentRange (17), The channel is operating in the low current measurement range outputCurrentBoundsExceeded (18), Output current is out of bounds outputFailureCurrentLimit (19) Hardware current limit (EHS) / trip (EDS, EBS) was exceeded
What is outputStatus?
A bitmask reporting this channel's health and operating condition -- e.g. whether it's on, externally inhibited, or tripped on a sense-voltage/current/temperature limit -- read to diagnose exactly why a channel isn't behaving as expected instead of just seeing it as 'off'.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.4 snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.4.1 snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputStatus.1
Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputStatus OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.19947 | wiener | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1 | crate | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3 | output | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2 | outputTable | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1 | outputEntry | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1.4 | outputStatus | WIENER-CRATE-MIB |