All MIBs › WIENER-CRATE-MIB › outputConfigMaxTerminalVoltage
outputConfigMaxTerminalVoltage
Module: WIENER-CRATE-MIB
OID (symbolic): WIENER-CRATE-MIB::outputConfigMaxTerminalVoltage
OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.22
Node type: OBJECT-TYPE
Type: Float
Access: read-write
Description: The maximum possible value of the terminal voltage
What is outputConfigMaxTerminalVoltage?
The maximum terminal voltage this channel's hardware is physically capable of supplying, the hardware ceiling underlying the module's rated voltage range.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.22 snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputConfigMaxTerminalVoltage
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.22.1 snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputConfigMaxTerminalVoltage.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.22.1 s <value>
Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputConfigMaxTerminalVoltage OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.19947 | wiener | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1 | crate | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3 | output | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2 | outputTable | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1 | outputEntry | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1.22 | outputConfigMaxTerminalVoltage | WIENER-CRATE-MIB |