WIENER-CRATE-MIB :: outputConfigMaxTemperature

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › WIENER-CRATE-MIB › outputConfigMaxTemperature

outputConfigMaxTemperature

Module: WIENER-CRATE-MIB

OID (symbolic): WIENER-CRATE-MIB::outputConfigMaxTemperature

OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.39

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The maximum possible value of outputSupervisionMaxTemperature.

What is outputConfigMaxTemperature?

The maximum value that can be configured for outputSupervisionMaxTemperature, i.e. the hardware/firmware ceiling bounding that alarm threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.39
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputConfigMaxTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.39.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputConfigMaxTemperature.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.39.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> outputConfigMaxTemperature.1

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputConfigMaxTemperature OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3outputWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2outputTableWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1outputEntryWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1.39outputConfigMaxTemperatureWIENER-CRATE-MIB