WIENER-CRATE-MIB :: outputConfigMaxSenseVoltage

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › WIENER-CRATE-MIB › outputConfigMaxSenseVoltage

outputConfigMaxSenseVoltage

Module: WIENER-CRATE-MIB

OID (symbolic): WIENER-CRATE-MIB::outputConfigMaxSenseVoltage

OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.21

Node type: OBJECT-TYPE

Type: Float

Access: read-write

Description: The maximum possible value of the sense voltage

What is outputConfigMaxSenseVoltage?

The maximum sense voltage this channel's hardware is physically capable of measuring/supplying, a fixed hardware ceiling rather than an admin-adjustable alarm threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.21
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputConfigMaxSenseVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.21.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputConfigMaxSenseVoltage.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.21.1 s <value>

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputConfigMaxSenseVoltage OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3outputWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2outputTableWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1outputEntryWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1.21outputConfigMaxSenseVoltageWIENER-CRATE-MIB