Type: OCTET STRING

Access: read-write

Description: Configuration Data raw access. This allows to read / write output channel specific user configuration data. This OID is intended for use by WIENER system software only and my not be accessed directly. snmpget: undefined behavior snmpset: OCTET STRING format for reading data (8 octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit OCTET STRING format used for writing data, or returned from the SNMP client after read/write (8+n octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit data numberOfOctets octets

What is outputConfigDataS?

Raw configuration-data access for this channel, intended per the source description strictly for WIENER's own system software rather than direct SNMP use; the value format encodes an offset and length in octets rather than a plain human-readable setting.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.1024
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputConfigDataS

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.1024.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputConfigDataS.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.1024.1 s <value>

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputConfigDataS OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3outputWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2outputTableWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1outputEntryWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1.1024outputConfigDataSWIENER-CRATE-MIB