WIENER-CRATE-MIB :: moduleEventStatus

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › WIENER-CRATE-MIB › moduleEventStatus

moduleEventStatus

Module: WIENER-CRATE-MIB

OID (symbolic): WIENER-CRATE-MIB::moduleEventStatus

OID (numeric): 1.3.6.1.4.1.19947.1.3.6.1.9

Node type: OBJECT-TYPE

Type: Bits

Access: read-only

Description: A bit string which shows the current module status. If a bit is set (1), the explanation is satisfied: moduleEventPowerFail (0), Event power fail generated by the MPOD controller in order to ramp down all HV's (ramp speed=1000V/s) moduleEventLiveInsertion (2), Event live insertion to prepare a hot plug of a module moduleEventService (4), Module event: Hardware failure detected (consult iseg Spezialelektronik GmbH). moduleHardwareLimitVoltageNotGood (5), Module Event: Hardware voltage limit is not in proper range, using for HV distributor modules with current mirror only. moduleEventInputError (6), Module event: There was an input error in connection with a module access moduleEventSafetyLoopNotGood (10), Module event: Safety loop is open. moduleEventSupplyNotGood (13), Module event: At least one of the supplies is not good. moduleEventTemperatureNotGood (14), Module event: Temperature was above the permitted threshold (for EDS/EHS temperature above 55 degr.C)

What is moduleEventStatus?

A bitmask of module-level event flags, e.g. a controller-driven power-fail ramp-down, a live-insertion (hot-plug) event, or a hardware service-required condition, read to see what's currently affecting the whole module rather than a single channel.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.6.1.9
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::moduleEventStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.6.1.9.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::moduleEventStatus.1

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::moduleEventStatus OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3outputWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.6moduleTableWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.6.1moduleEntryWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.6.1.9moduleEventStatusWIENER-CRATE-MIB