WIENER-CRATE-MIB :: moduleDoClear

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › WIENER-CRATE-MIB › moduleDoClear

moduleDoClear

Module: WIENER-CRATE-MIB

OID (symbolic): WIENER-CRATE-MIB::moduleDoClear

OID (numeric): 1.3.6.1.4.1.19947.1.3.6.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: All events of the module will be cleared.

What is moduleDoClear?

Writing doClear clears all currently latched event flags on this module, e.g. after resolving whatever tripped moduleEventStatus, so the module's status reflects only new events going forward.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.6.1.11
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::moduleDoClear

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.6.1.11.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::moduleDoClear.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.6.1.11.1 i <value>

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::moduleDoClear OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3outputWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.6moduleTableWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.6.1moduleEntryWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.6.1.11moduleDoClearWIENER-CRATE-MIB