All MIBs › WIENER-CRATE-MIB › groupsSwitch
groupsSwitch
Module: WIENER-CRATE-MIB
OID (symbolic): WIENER-CRATE-MIB::groupsSwitch
OID (numeric): 1.3.6.1.4.1.19947.1.3.4.1.9
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Read: This function is not defined with groups of output channels.
Write: Switch the state of all channels of a group. If any channel is On, and the write value is Off, then all channels will switch off. If any channel is Off, and the write value is On, and if no other signals (mainInhibit, outputInhibit, outputEmergencyOff or outputFailureMaxCurrent) are active, then all channels will switch on.
If the write value is resetEmergencyOff, then all channels will leave the state EmergencyOff. A write of clearEvents is necessary before the voltage can ramp up again. If the write value is setEmergencyOff, then all channels will have the state EmergencyOff, which means that the High Voltage will switch off without a ramp and reset of the outputVoltage to null volt.
If the write value is disableKILL, then all channels will switch to disableKill (outputStatus outputDisableKill). If the write value is enableKILL, then all channels will switch to enableKill (outputStatus outputEnableKill).
If the write value is clearEvents, then all failure messages of the outputStatus will be cleared (all channel events, all module events and the state outputEmergencyOff will be reset).
For a detailed description of the different group numbers available look at the outputGroup OID above.
What is groupsSwitch?
Writes switch every channel in a given output group on or off together (subject to the same inhibit/emergency-off conditions as outputSwitch), while a read simply isn't meaningful for a group per the source description.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.4.1.9 snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::groupsSwitch
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.4.1.9.1 snmpget -v2c -c public <target> WIENER-CRATE-MIB::groupsSwitch.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.4.1.9.1 i <value>
Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::groupsSwitch OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.19947 | wiener | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1 | crate | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3 | output | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.4 | groupsTable | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.4.1 | groupsEntry | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.4.1.9 | groupsSwitch | WIENER-CRATE-MIB |