WIENER-CRATE-MIB :: fanSwitchOffDelay

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › WIENER-CRATE-MIB › fanSwitchOffDelay

fanSwitchOffDelay

Module: WIENER-CRATE-MIB

OID (symbolic): WIENER-CRATE-MIB::fanSwitchOffDelay

OID (numeric): 1.3.6.1.4.1.19947.1.7.5

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The maximum time in seconds for which the fans will continue running after the power supply has been switched off. This feature is used to cool down the electronics after switching off.

What is fanSwitchOffDelay?

How many seconds (up to 900) the fans keep running after the power supply is switched off, giving hot electronics time to cool down before the fans stop.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.7.5
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::fanSwitchOffDelay

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.7.5.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::fanSwitchOffDelay.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.7.5.1 i <value>

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::fanSwitchOffDelay OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.7fantrayWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.7.5fanSwitchOffDelayWIENER-CRATE-MIB