All MIBs › VDSL-LINE-EXT-SCM-MIB › vdslLineSCMPhysBandCurrSnrMgn
vdslLineSCMPhysBandCurrSnrMgn
Module: VDSL-LINE-EXT-SCM-MIB
OID (symbolic): VDSL-LINE-EXT-SCM-MIB::vdslLineSCMPhysBandCurrSnrMgn
OID (numeric): 1.3.6.1.2.1.10.228.1.1.2.1.7
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Noise margin as seen by this Vtu and band with respect to its received signal in 0.25 dB.
What is vdslLineSCMPhysBandCurrSnrMgn?
This read-only value, in units of 0.25 dB, reports the noise margin this VDSL transceiver unit measures on this band relative to its received signal. Admins monitor it as a key indicator of line quality on this frequency band, with a higher margin meaning more headroom before errors occur. For example, a vdslLineSCMPhysBandCurrSnrMgn dropping close to zero on a band signals the line is close to losing sync on that frequency range, warranting investigation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.228.1.1.2.1.7 snmpwalk -v2c -c public <target> VDSL-LINE-EXT-SCM-MIB::vdslLineSCMPhysBandCurrSnrMgn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.10.228.1.1.2.1.7.1 snmpget -v2c -c public <target> VDSL-LINE-EXT-SCM-MIB::vdslLineSCMPhysBandCurrSnrMgn.1
Start monitoring VDSL access equipment, SCM line coding (band-parameter/SNR-margin status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VDSL-LINE-EXT-SCM-MIB::vdslLineSCMPhysBandCurrSnrMgn OID value, configure state conditions and alerts, and monitor any VDSL access equipment, SCM line coding (band-parameter/SNR-margin status) from a single console.
How to Use in IPNetwork Monitor
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | APERTUS-NPG-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.10 | transmission | CHECKPOINT-MIB-2 |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.10.228 | vdslExtSCMMIB | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1 | vdslLineExtSCMMib | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1.1 | vdslLineExtSCMMibObjects | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1.1.2 | vdslLineSCMPhysBandTable | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1.1.2.1 | vdslLineSCMPhysBandEntry | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1.1.2.1.7 | vdslLineSCMPhysBandCurrSnrMgn | VDSL-LINE-EXT-SCM-MIB |