All MIBs › VDSL-LINE-EXT-SCM-MIB › vdslLineSCMPhysBandCurrCenterFrequency
vdslLineSCMPhysBandCurrCenterFrequency
Module: VDSL-LINE-EXT-SCM-MIB
OID (symbolic): VDSL-LINE-EXT-SCM-MIB::vdslLineSCMPhysBandCurrCenterFrequency
OID (numeric): 1.3.6.1.2.1.10.228.1.1.2.1.3
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: The current center frequency in Hz for this band.
What is vdslLineSCMPhysBandCurrCenterFrequency?
This read-only value reports the current center frequency, in Hz, actually in use for this band on the physical VDSL line. Admins compare it against the configured profile value to confirm the line is actually operating at the intended frequency. For example, a vdslLineSCMPhysBandCurrCenterFrequency that differs from the configured profile value might indicate the line negotiated a different frequency plan during training.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.228.1.1.2.1.3 snmpwalk -v2c -c public <target> VDSL-LINE-EXT-SCM-MIB::vdslLineSCMPhysBandCurrCenterFrequency
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.10.228.1.1.2.1.3.1 snmpget -v2c -c public <target> VDSL-LINE-EXT-SCM-MIB::vdslLineSCMPhysBandCurrCenterFrequency.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> vdslLineSCMPhysBandCurrCenterFrequency.1
Start monitoring VDSL access equipment, SCM line coding (band-parameter/SNR-margin status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VDSL-LINE-EXT-SCM-MIB::vdslLineSCMPhysBandCurrCenterFrequency OID value, configure state conditions and alerts, and monitor any VDSL access equipment, SCM line coding (band-parameter/SNR-margin status) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | APERTUS-NPG-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.10 | transmission | CHECKPOINT-MIB-2 |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.10.228 | vdslExtSCMMIB | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1 | vdslLineExtSCMMib | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1.1 | vdslLineExtSCMMibObjects | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1.1.2 | vdslLineSCMPhysBandTable | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1.1.2.1 | vdslLineSCMPhysBandEntry | VDSL-LINE-EXT-SCM-MIB |
| 1.3.6.1.2.1.10.228.1.1.2.1.3 | vdslLineSCMPhysBandCurrCenterFrequency | VDSL-LINE-EXT-SCM-MIB |