upsRunTimeCalibration
Module: UPS2-MIB
OID (symbolic): UPS2-MIB::upsRunTimeCalibration
OID (numeric): 1.3.6.1.4.1.52.4.1.1.10.3.1.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This object may be written to initiate or terminate the test used to calibrate the returned run time value. This test will only run if battery capacity is 100%. Results of this test can be retrieved by upsEstimatedRunTimeRemaining. Valid values for writing are 1 (initiate test) and 2 (terminate test). In addition, this object may be read to determine whether the test is currently running. Valid values for reading are 3 (test is in progress) and 4 (test is not in progress).
What is upsRunTimeCalibration?
Controls the UPS's run-time calibration test: an admin writes performTest(1) to start it (only runs at 100% battery capacity) or abortTest(2) to stop it, and reads back testInProgress(3) or testNotInProgress(4) to check whether it's currently running.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.10.3.1.1.5 snmpwalk -v2c -c public <target> UPS2-MIB::upsRunTimeCalibration
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.10.3.1.1.5.1 snmpget -v2c -c public <target> UPS2-MIB::upsRunTimeCalibration.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.1.10.3.1.1.5.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> upsRunTimeCalibration.1
Start monitoring Cabletron Systems UPS product line, SmartUPS/MatrixUPS models (battery/input-output power/environmental status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the UPS2-MIB::upsRunTimeCalibration OID value, configure state conditions and alerts, and monitor any Cabletron Systems UPS product line, SmartUPS/MatrixUPS models (battery/input-output power/environmental status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-ISDN-CONFIGURATION-MIB |
| 1.3.6.1.4.1.52.4.1.1 | ctPhysical | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1.10 | ctUPS | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.1.10.3 | upsBattery | UPS2-MIB |
| 1.3.6.1.4.1.52.4.1.1.10.3.1 | upsBatteryTable | UPS2-MIB |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1 | upsBatteryEntry | UPS2-MIB |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.5 | upsRunTimeCalibration | UPS2-MIB |