All MIBs › UPS2-MIB › upsExtMeasMaxHumidityAlarmControl
upsExtMeasMaxHumidityAlarmControl
Module: UPS2-MIB
OID (symbolic): UPS2-MIB::upsExtMeasMaxHumidityAlarmControl
OID (numeric): 1.3.6.1.4.1.52.4.1.1.10.8.1.1.15
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The alarm enable state for the External Measurement Unit's upper humidity limit. If enabled, an alarm will be sent when the ambient relative humidity rises above the upper humidity limit.
What is upsExtMeasMaxHumidityAlarmControl?
Enables or disables (enable(1)/disable(2)) whether the External Measurement Unit sounds an alarm when ambient humidity rises above the upsExtMeasMaxHumidity limit, letting an admin silence the high-humidity alarm independently of the limit setting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.10.8.1.1.15 snmpwalk -v2c -c public <target> UPS2-MIB::upsExtMeasMaxHumidityAlarmControl
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.10.8.1.1.15.1 snmpget -v2c -c public <target> UPS2-MIB::upsExtMeasMaxHumidityAlarmControl.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.1.10.8.1.1.15.1 i <value>
Start monitoring Cabletron Systems UPS product line, SmartUPS/MatrixUPS models (battery/input-output power/environmental status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the UPS2-MIB::upsExtMeasMaxHumidityAlarmControl OID value, configure state conditions and alerts, and monitor any Cabletron Systems UPS product line, SmartUPS/MatrixUPS models (battery/input-output power/environmental status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-ISDN-CONFIGURATION-MIB |
| 1.3.6.1.4.1.52.4.1.1 | ctPhysical | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1.10 | ctUPS | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.1.10.8 | upsExtMeas | UPS2-MIB |
| 1.3.6.1.4.1.52.4.1.1.10.8.1 | upsExtMeasTable | UPS2-MIB |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1 | upsExtMeasEntry | UPS2-MIB |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.15 | upsExtMeasMaxHumidityAlarmControl | UPS2-MIB |