UPS-MIB :: upsBatteryCurrent

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsUPS-MIBupsBatteryCurrent

upsBatteryCurrent

Module: UPS-MIB

OID (symbolic): UPS-MIB::upsBatteryCurrent

OID (numeric): 1.3.6.1.2.1.33.1.2.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The present battery current.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.33.1.2.6
snmpwalk -v2c -c public <target> UPS-MIB::upsBatteryCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.33.1.2.6.1
snmpget -v2c -c public <target> UPS-MIB::upsBatteryCurrent.1

Start monitoring vendor-neutral, standards-based MIB, Uninterruptible Power Supply (UPS) systems (battery health/runtime/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the UPS-MIB::upsBatteryCurrent OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB, Uninterruptible Power Supply (UPS) systems (battery health/runtime/alarm status) from a single console.

How to Use in IPNetwork Monitor

Select an Uninterruptible Power Supply (UPS) system as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type upsBatteryCurrent into the Find box to locate it in the OID tree, then select it and click OK. It reports the UPS battery's present current, in units of 0.1 Amp DC. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal charging/discharging baseline, since an unexpected current reading can indicate a battery or charging fault. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.33upsMIBUPS-MIB
1.3.6.1.2.1.33.1upsObjectsUPS-MIB
1.3.6.1.2.1.33.1.2upsBatteryUPS-MIB
1.3.6.1.2.1.33.1.2.6upsBatteryCurrentUPS-MIB