UPS-MIB :: upsAutoRestart

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsUPS-MIBupsAutoRestart

upsAutoRestart

Module: UPS-MIB

OID (symbolic): UPS-MIB::upsAutoRestart

OID (numeric): 1.3.6.1.2.1.33.1.8.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.

What is upsAutoRestart?

This object controls whether the UPS system automatically restarts after a shutdown that occurred during a power loss, such as one triggered by upsShutdownAfterDelay or a depleted battery. Admins set it to off in environments where an operator must manually confirm it's safe to bring systems back online after an outage, and to on where unattended automatic recovery is preferred. With this set to off, a UPS that shut down during an overnight power failure will stay off until someone manually restarts it, even after utility power returns.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.33.1.8.5
snmpwalk -v2c -c public <target> UPS-MIB::upsAutoRestart

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.33.1.8.5.1
snmpget -v2c -c public <target> UPS-MIB::upsAutoRestart.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.2.1.33.1.8.5.1 i <value>

Start monitoring vendor-neutral, standards-based MIB, Uninterruptible Power Supply (UPS) systems (battery health/runtime/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the UPS-MIB::upsAutoRestart OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB, Uninterruptible Power Supply (UPS) systems (battery health/runtime/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.33upsMIBUPS-MIB
1.3.6.1.2.1.33.1upsObjectsUPS-MIB
1.3.6.1.2.1.33.1.8upsControlUPS-MIB
1.3.6.1.2.1.33.1.8.5upsAutoRestartUPS-MIB