TAIT-INFRA93SERIES-MIB :: pmuAlarmShutdownImminent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TAIT-INFRA93SERIES-MIB › pmuAlarmShutdownImminent

pmuAlarmShutdownImminent

Module: TAIT-INFRA93SERIES-MIB

OID (symbolic): TAIT-INFRA93SERIES-MIB::pmuAlarmShutdownImminent

OID (numeric): 1.3.6.1.4.1.3570.2.2.2.1.3.5.6

Node type: OBJECT-TYPE

Type: AlarmState

Access: read-only

Description: Shut-down imminent alarm. A battery is currently powering the base station and its voltage has fallen below the configured power shut-down voltage. The PMU will shut down 30 seconds after activating this alarm. Range: unavailable(0), cleared(1), raised(2), disabled(3)

What is pmuAlarmShutdownImminent?

Indicates the base station is currently running on battery and that battery's voltage has fallen below the configured shutdown threshold; the PMU will shut down 30 seconds after this alarm activates. This is a time-critical alarm -- admins should treat it as an imminent outage warning requiring immediate power restoration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3570.2.2.2.1.3.5.6
snmpwalk -v2c -c public <target> TAIT-INFRA93SERIES-MIB::pmuAlarmShutdownImminent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3570.2.2.2.1.3.5.6.1
snmpget -v2c -c public <target> TAIT-INFRA93SERIES-MIB::pmuAlarmShutdownImminent.1

Start monitoring Tait TB93XX-series DMR/analog base station (license/RF-status/RSSI monitoring) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TAIT-INFRA93SERIES-MIB::pmuAlarmShutdownImminent OID value, configure state conditions and alerts, and monitor any Tait TB93XX-series DMR/analog base station (license/RF-status/RSSI monitoring) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3570taitTAIT-COMMON-MIB
1.3.6.1.4.1.3570.2taitGenericTAIT-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3570.2.2infra93MIBTAIT-INFRA93SERIES-MIB
1.3.6.1.4.1.3570.2.2.2monitoredTAIT-INFRA93SERIES-MIB
1.3.6.1.4.1.3570.2.2.2.1mibObjectsTAIT-INFRA93SERIES-MIB
1.3.6.1.4.1.3570.2.2.2.1.3alarmsTAIT-INFRA93SERIES-MIB
1.3.6.1.4.1.3570.2.2.2.1.3.5pmuAlarmsTAIT-INFRA93SERIES-MIB
1.3.6.1.4.1.3570.2.2.2.1.3.5.6pmuAlarmShutdownImminentTAIT-INFRA93SERIES-MIB