SYNSO-UPSMIB :: syupsSignalType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSYNSO-UPSMIBsyupsSignalType

syupsSignalType

Module: SYNSO-UPSMIB

OID (symbolic): SYNSO-UPSMIB::syupsSignalType

OID (numeric): 1.3.6.1.4.1.9557.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The signaling method between the UPS and software.

When the basicSignal used, the UPS changes the voltage level of some specific pins to notify the software of what critical event occurs. Usually, the UPS will inform software when a power failure or a low battery condition occurs. On the other hand, the software can change the voltage signal of a specific pin to ask the UPS to shut down (turn off).

When the smartSignal used, the UPS asks like a standard communication device (such as mouse or modem). That means the UPS and software communicate with each other using a pre-defined protocol. The protocol should include at least the following commands: - query the power status of the UPS - query the power data of the UPS - command the UPS to shut down

What is syupsSignalType?

Whether the UPS communicates with this software using simple voltage-level signaling on specific pins (basicSignal) or a full command/response protocol like a modem (smartSignal); this determines whether the agent can only react to raw power-fail/low-battery/shutdown signals or can actively query detailed power status and data.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9557.1.1.4
snmpwalk -v2c -c public <target> SYNSO-UPSMIB::syupsSignalType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9557.1.1.4.1
snmpget -v2c -c public <target> SYNSO-UPSMIB::syupsSignalType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9557.1.1.4.1 i <value>

Start monitoring SYNSO UPS, uninterruptible power supply (platform identity/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SYNSO-UPSMIB::syupsSignalType OID value, configure state conditions and alerts, and monitor any SYNSO UPS, uninterruptible power supply (platform identity/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9557synsoSYNSO-UPSMIB
1.3.6.1.4.1.9557.1synsoUpsSoftwareSYNSO-UPSMIB
1.3.6.1.4.1.9557.1.1syupsBasicSettingSYNSO-UPSMIB
1.3.6.1.4.1.9557.1.1.4syupsSignalTypeSYNSO-UPSMIB