SUN-ILOM-CONTROL-MIB :: ilomCtrlRedundancyAction

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SUN-ILOM-CONTROL-MIB › ilomCtrlRedundancyAction

ilomCtrlRedundancyAction

Module: SUN-ILOM-CONTROL-MIB

OID (symbolic): SUN-ILOM-CONTROL-MIB::ilomCtrlRedundancyAction

OID (numeric): 1.3.6.1.4.1.42.2.175.102.12.2

Node type: OBJECT-TYPE

Type: ILOMCtrlRedundancyAction

Access: read-write

Description: This action is used to promote or demote this device from active or standy status.

What is ilomCtrlRedundancyAction?

Write-only action used to promote this SP to active or demote it to standby in a redundant configuration, used to force a controlled failover for maintenance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.42.2.175.102.12.2
snmpwalk -v2c -c public <target> SUN-ILOM-CONTROL-MIB::ilomCtrlRedundancyAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.42.2.175.102.12.2.1
snmpget -v2c -c public <target> SUN-ILOM-CONTROL-MIB::ilomCtrlRedundancyAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.42.2.175.102.12.2.1 s <value>

Start monitoring Sun/Oracle server ILOM service processor (NTP/LDAP/RADIUS remote-access config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SUN-ILOM-CONTROL-MIB::ilomCtrlRedundancyAction OID value, configure state conditions and alerts, and monitor any Sun/Oracle server ILOM service processor (NTP/LDAP/RADIUS remote-access config) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.42sunAGENT-STATS-MIB2
1.3.6.1.4.1.42.2prodAGENT-STATS-MIB2
1.3.6.1.4.1.42.2.175ilomSUN-HW-CTRL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.42.2.175.102ilomCtrlMIBSUN-ILOM-CONTROL-MIB
1.3.6.1.4.1.42.2.175.102.12ilomCtrlRedundancySUN-ILOM-CONTROL-MIB
1.3.6.1.4.1.42.2.175.102.12.2ilomCtrlRedundancyActionSUN-ILOM-CONTROL-MIB