SUN-FM-MIB :: sunFmResourceCount

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SUN-FM-MIB › sunFmResourceCount

sunFmResourceCount

Module: SUN-FM-MIB

OID (symbolic): SUN-FM-MIB::sunFmResourceCount

OID (numeric): 1.3.6.1.4.1.42.2.195.1.4

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The number of managed elements currently believed by the fault manager to be faulty.

What is sunFmResourceCount?

The total number of managed elements the fault manager currently believes are faulty system-wide, a single top-level number an admin can alert on before drilling into the individual resource table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.42.2.195.1.4
snmpwalk -v2c -c public <target> SUN-FM-MIB::sunFmResourceCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.42.2.195.1.4.1
snmpget -v2c -c public <target> SUN-FM-MIB::sunFmResourceCount.1

Start monitoring Sun/Oracle SPARC/x86 server running Solaris FMA (diagnosed hardware fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SUN-FM-MIB::sunFmResourceCount OID value, configure state conditions and alerts, and monitor any Sun/Oracle SPARC/x86 server running Solaris FMA (diagnosed hardware fault status) from a single console.

How to Use in IPNetwork Monitor

Select a Sun/Oracle SPARC/x86 server running Solaris FMA (diagnosed hardware fault status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type sunFmResourceCount into the Find box to locate it in the OID tree, then select it and click OK. The number of managed elements currently believed by the fault manager to be faulty. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.42sunAGENT-STATS-MIB2
1.3.6.1.4.1.42.2prodAGENT-STATS-MIB2
Numeric OIDNameModule
1.3.6.1.4.1.42.2.195fmSUN-FM-MIB
1.3.6.1.4.1.42.2.195.1sunFmMIBSUN-FM-MIB
1.3.6.1.4.1.42.2.195.1.4sunFmResourceCountSUN-FM-MIB