SUN-FM-MIB :: sunFmFaultEventASRU

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SUN-FM-MIB › sunFmFaultEventASRU

sunFmFaultEventASRU

Module: SUN-FM-MIB

OID (symbolic): SUN-FM-MIB::sunFmFaultEventASRU

OID (numeric): 1.3.6.1.4.1.42.2.195.1.2.1.6

Node type: OBJECT-TYPE

Type: URLString

Access: read-only

Description: Sun FMRI of the Automated System Reconfiguration Unit (ASRU) that is believed to contain the specified fault or defect.

What is sunFmFaultEventASRU?

The Sun FMRI of the Automated System Reconfiguration Unit believed to contain this fault, the component the system can automatically take offline or reconfigure around to isolate the problem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.42.2.195.1.2.1.6
snmpwalk -v2c -c public <target> SUN-FM-MIB::sunFmFaultEventASRU

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.42.2.195.1.2.1.6.1
snmpget -v2c -c public <target> SUN-FM-MIB::sunFmFaultEventASRU.1

Start monitoring Sun/Oracle SPARC/x86 server running Solaris FMA (diagnosed hardware fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SUN-FM-MIB::sunFmFaultEventASRU OID value, configure state conditions and alerts, and monitor any Sun/Oracle SPARC/x86 server running Solaris FMA (diagnosed hardware fault status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.42sunAGENT-STATS-MIB2
1.3.6.1.4.1.42.2prodAGENT-STATS-MIB2
Numeric OIDNameModule
1.3.6.1.4.1.42.2.195fmSUN-FM-MIB
1.3.6.1.4.1.42.2.195.1sunFmMIBSUN-FM-MIB
1.3.6.1.4.1.42.2.195.1.2sunFmFaultEventTableSUN-FM-MIB
1.3.6.1.4.1.42.2.195.1.2.1sunFmFaultEventEntrySUN-FM-MIB
1.3.6.1.4.1.42.2.195.1.2.1.6sunFmFaultEventASRUSUN-FM-MIB