All MIBs › STORMSHIELD-HA-MIB › snsNbFaultyHALinks
snsNbFaultyHALinks
Module: STORMSHIELD-HA-MIB
OID (symbolic): STORMSHIELD-HA-MIB::snsNbFaultyHALinks
OID (numeric): 1.3.6.1.4.1.11256.1.11.6
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Number of faulty HA links
What is snsNbFaultyHALinks?
Counts how many of the configured HA links are currently faulty. A non-zero value reduces the cluster's heartbeat/sync redundancy and, if it reaches the total link count, risks a split-brain if the last link fails.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11256.1.11.6 snmpwalk -v2c -c public <target> STORMSHIELD-HA-MIB::snsNbFaultyHALinks
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11256.1.11.6.1 snmpget -v2c -c public <target> STORMSHIELD-HA-MIB::snsNbFaultyHALinks.1
Start monitoring Stormshield firewall/UTM appliance, HA cluster pair (failover/sync status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the STORMSHIELD-HA-MIB::snsNbFaultyHALinks OID value, configure state conditions and alerts, and monitor any Stormshield firewall/UTM appliance, HA cluster pair (failover/sync status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11256 | netasq | NETASQ-SMI-MIB |
| 1.3.6.1.4.1.11256.1 | netasqMIB | NETASQ-SMI-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11256.1.11 | snsHA | STORMSHIELD-HA-MIB |
| 1.3.6.1.4.1.11256.1.11.6 | snsNbFaultyHALinks | STORMSHIELD-HA-MIB |