snmpEventEvents

Module: SNMPv2-M2M-MIB

OID (symbolic): SNMPv2-M2M-MIB::snmpEventEvents

OID (numeric): 1.3.6.1.6.3.2.1.2.2.1.4

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of events caused by event generators associated with this snmpEvent entry.

What is snmpEventEvents?

A running count of how many times event generators tied to this entry have actually fired, giving an admin a quick way to see which configured events are seeing real activity versus sitting idle.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.6.3.2.1.2.2.1.4
snmpwalk -v2c -c public <target> SNMPv2-M2M-MIB::snmpEventEvents

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.6.3.2.1.2.2.1.4.1
snmpget -v2c -c public <target> SNMPv2-M2M-MIB::snmpEventEvents.1

Start monitoring vendor-neutral, standards-based MIB, SNMP-managed network devices and management stations (Manager-to-Manager alarm coordination) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNMPv2-M2M-MIB::snmpEventEvents OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB, SNMP-managed network devices and management stations (Manager-to-Manager alarm coordination) from a single console.

How to Use in IPNetwork Monitor

Select a device implementing SNMPv2-M2M-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type snmpEventEvents into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of events caused by event generators associated with this snmpEvent entry. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.6snmpV2DASAN-DHCP-MIB
1.3.6.1.6.3snmpModulesOSBRiDGE5XLi-MIB
Numeric OIDNameModule
1.3.6.1.6.3.2snmpM2MSNMPv2-M2M-MIB
1.3.6.1.6.3.2.1snmpM2MObjectsSNMPv2-M2M-MIB
1.3.6.1.6.3.2.1.2snmpEventSNMPv2-M2M-MIB
1.3.6.1.6.3.2.1.2.2snmpEventTableSNMPv2-M2M-MIB
1.3.6.1.6.3.2.1.2.2.1snmpEventEntrySNMPv2-M2M-MIB
1.3.6.1.6.3.2.1.2.2.1.4snmpEventEventsSNMPv2-M2M-MIB