SITEBOSS-220-STD-MIB :: esPointName

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SITEBOSS-220-STD-MIB › esPointName

esPointName

Module: SITEBOSS-220-STD-MIB

OID (symbolic): SITEBOSS-220-STD-MIB::esPointName

OID (numeric): 1.3.6.1.4.1.3052.43.1.1.1.1.4

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: The name of the point on an EventSensor. For example, 'AC temp' (in the case of the temperature sensor on an EventSensor). There can be multiple points of the same point class on an EventSensor (e.g., 8 contact closures) and multiple sensor classes on an EventSensor (e.g., temperature, contact closure, humidity). If the point referenced by a given point index is solitary (e.g., temperature sensor, because there can be only one on an EventSensor), then this object reads as ''. Setting this object for solitary point indices sets the EventSensor name only. On the other hand, if a given point is among other points of the same point class on an EventSensor, then this object reads as ''. Setting this object for these NON- solitary point indices sets the sensor name only - not the EventSensor name.

What is esPointName?

The configurable name of this point, such as 'AC temp'; for a sensor class that only has one instance on an EventSensor, setting this actually renames the EventSensor itself, while for a class with multiple instances (like 8 contact closures) it renames just this one sensor.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3052.43.1.1.1.1.4
snmpwalk -v2c -c public <target> SITEBOSS-220-STD-MIB::esPointName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3052.43.1.1.1.1.4.1
snmpget -v2c -c public <target> SITEBOSS-220-STD-MIB::esPointName.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3052.43.1.1.1.1.4.1 s <value>

Start monitoring Asentria SiteBoss 220 remote site monitor (analog/digital sensor point/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SITEBOSS-220-STD-MIB::esPointName OID value, configure state conditions and alerts, and monitor any Asentria SiteBoss 220 remote site monitor (analog/digital sensor point/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3052asentriaASENTRIA-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3052.43s220SITEBOSS-220-STD-MIB
1.3.6.1.4.1.3052.43.1statusSITEBOSS-220-STD-MIB
1.3.6.1.4.1.3052.43.1.1eventSensorStatusSITEBOSS-220-STD-MIB
1.3.6.1.4.1.3052.43.1.1.1esPointTableSITEBOSS-220-STD-MIB
1.3.6.1.4.1.3052.43.1.1.1.1esPointEntrySITEBOSS-220-STD-MIB
1.3.6.1.4.1.3052.43.1.1.1.1.4esPointNameSITEBOSS-220-STD-MIB