All MIBs › SIEMENS-DUPLEXWRITE-MIB › sieDWDuplexStatus
sieDWDuplexStatus
Module: SIEMENS-DUPLEXWRITE-MIB
OID (symbolic): SIEMENS-DUPLEXWRITE-MIB::sieDWDuplexStatus
OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.8.3.1.1.17
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The status of the DW group where this device is part of: online: the device is in perfect order (GET/SET) error: the device had a fault (GET/SET) recover: the device is working on a catch-up (GET) disable: stop operation of this device (GET/SET) simplex: simple SCSI device (GET) na: not available as DuplexDisk piece (GET) preferred: piece used for read (GET) multipath: disk not accessible (MultiPath) (GET) cluster: disk on other cluster node (GET) missing: one disk of the DW group is missing (GET)
The highest 8 bit of the value are used for additional status information: Bit field: Bit 0 - most recent Bit 1 - root Bit 2 - force active Bit 3 - hotspare Bit 4 - broken Bit 5 - reserved ... Bit 7 - reserved
What is sieDWDuplexStatus?
Reports (and, by writing, can force) the state of the DuplexWrite mirror group this disk belongs to: online means healthy, error means a fault occurred, recover means it's currently catching up its mirror, disable stops the device, simplex means it's a plain unmirrored SCSI disk, and other values flag conditions like multipath-inaccessible, on another cluster node, missing, or preferred-for-reads; extra status bits in the top byte flag things like 'most recent', 'root', 'force active', or 'hotspare'.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.8.3.1.1.17 snmpwalk -v2c -c public <target> SIEMENS-DUPLEXWRITE-MIB::sieDWDuplexStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.8.3.1.1.17.1 snmpget -v2c -c public <target> SIEMENS-DUPLEXWRITE-MIB::sieDWDuplexStatus.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.231.2.10.2.2.8.3.1.1.17.1 i <value>
Start monitoring Siemens server/storage cluster node (data-mirroring/duplex-write status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SIEMENS-DUPLEXWRITE-MIB::sieDWDuplexStatus OID value, configure state conditions and alerts, and monitor any Siemens server/storage cluster node (data-mirroring/duplex-write status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.2 | sniProductMibs | Application-Monitoring-MIB |
| 1.3.6.1.4.1.231.2.10 | sniExtensions | DESKTRAP-MIB |
| 1.3.6.1.4.1.231.2.10.2 | sniServerMgmt | FSC-SWITCH-MIB |
| 1.3.6.1.4.1.231.2.10.2.2 | sniCommon | FSC-SWITCH-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.2.10.2.2.8 | sieDuplexWrite | SIEMENS-DUPLEXWRITE-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.8.3 | sieDWContainer | SIEMENS-DUPLEXWRITE-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.8.3.1 | sieDWDeviceTable | SIEMENS-DUPLEXWRITE-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.8.3.1.1 | sieDWDevice | SIEMENS-DUPLEXWRITE-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.8.3.1.1.17 | sieDWDuplexStatus | SIEMENS-DUPLEXWRITE-MIB |