SIAE-RADIO-SYSTEM-MIB :: radioPtxHysteresisValue

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SIAE-RADIO-SYSTEM-MIB › radioPtxHysteresisValue

radioPtxHysteresisValue

Module: SIAE-RADIO-SYSTEM-MIB

OID (symbolic): SIAE-RADIO-SYSTEM-MIB::radioPtxHysteresisValue

OID (numeric): 1.3.6.1.4.1.3373.1103.80.70

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Defines the delta value associated to the radioPtx before having a new trap generation (radioPtxChange TRAP). The zero value is not allowed.

What is radioPtxHysteresisValue?

Hysteresis in dB (default 3, zero not allowed) the transmitted power must change by before a new transmit-level change trap is generated. With 3, a change of less than 3 dB sends nothing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3373.1103.80.70
snmpwalk -v2c -c public <target> SIAE-RADIO-SYSTEM-MIB::radioPtxHysteresisValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3373.1103.80.70.1
snmpget -v2c -c public <target> SIAE-RADIO-SYSTEM-MIB::radioPtxHysteresisValue.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3373.1103.80.70.1 i <value>

Start monitoring SIAE MICROELETTRONICA microwave radio-link equipment (radio/XPIC pairing configuration/status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SIAE-RADIO-SYSTEM-MIB::radioPtxHysteresisValue OID value, configure state conditions and alerts, and monitor any SIAE MICROELETTRONICA microwave radio-link equipment (radio/XPIC pairing configuration/status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3373siaeMicroelettronicaSpaSIAE-TREE-MIB
1.3.6.1.4.1.3373.1103siaeMibSIAE-TREE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3373.1103.80radioSystemSIAE-RADIO-SYSTEM-MIB
1.3.6.1.4.1.3373.1103.80.70radioPtxHysteresisValueSIAE-RADIO-SYSTEM-MIB