SEI-SMI :: juiceBoxMainSystemVoltage

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SEI-SMI › juiceBoxMainSystemVoltage

juiceBoxMainSystemVoltage

Module: SEI-SMI

OID (symbolic): SEI-SMI::juiceBoxMainSystemVoltage

OID (numeric): 1.3.6.1.4.1.20364.1.1.2.1

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Measured system voltage in millivolts .

What is juiceBoxMainSystemVoltage?

This read-only Gauge32, in millivolts, reports the JuiceBox's measured internal system voltage. An admin monitors this as a basic power-health indicator for the PoE injector chassis itself, separate from per-port PD power. For example, a reading drifting well below the expected nominal (e.g. under 11000 mV on a 12V system) could signal a failing power supply.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.20364.1.1.2.1
snmpwalk -v2c -c public <target> SEI-SMI::juiceBoxMainSystemVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.20364.1.1.2.1.1
snmpget -v2c -c public <target> SEI-SMI::juiceBoxMainSystemVoltage.1

Start monitoring System Engineering International JuiceBox product line device (base enterprise OID registration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SEI-SMI::juiceBoxMainSystemVoltage OID value, configure state conditions and alerts, and monitor any System Engineering International JuiceBox product line device (base enterprise OID registration) from a single console.

How to Use in IPNetwork Monitor

Select a System Engineering International JuiceBox product line device (base enterprise OID registration) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type juiceBoxMainSystemVoltage into the Find box to locate it in the OID tree, then select it and click OK. It reports the measured system voltage in millivolts . On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline (in milliVolts), since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.20364seiSEI-SMI
1.3.6.1.4.1.20364.1juiceBoxPseSEI-SMI
1.3.6.1.4.1.20364.1.1juiceBoxObjectsSEI-SMI
1.3.6.1.4.1.20364.1.1.2juiceBoxMainObjectsSEI-SMI
1.3.6.1.4.1.20364.1.1.2.1juiceBoxMainSystemVoltageSEI-SMI