SAMSUNG-DIAGNOSTICS-MIB :: scmDiagnosticsDeviceErrors

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSAMSUNG-DIAGNOSTICS-MIBscmDiagnosticsDeviceErrors

scmDiagnosticsDeviceErrors

Module: SAMSUNG-DIAGNOSTICS-MIB

OID (symbolic): SAMSUNG-DIAGNOSTICS-MIB::scmDiagnosticsDeviceErrors

OID (numeric): 1.3.6.1.4.1.236.11.5.11.64.1.2.1.7

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: The number of errors detected on this device. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. However, it is recommended that this object be initialized to zero.

What is scmDiagnosticsDeviceErrors?

This counter reports the number of errors detected on this device; per its DESCRIPTION it has no defined initial value as a Counter type, though implementations are recommended to initialize it to zero. An admin watches this to spot a component accumulating faults over time, such as a scanner reporting repeated paper-jam errors. For example, a rapidly climbing scmDiagnosticsDeviceErrors count on the fuser motor could justify scheduling preventive maintenance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.236.11.5.11.64.1.2.1.7
snmpwalk -v2c -c public <target> SAMSUNG-DIAGNOSTICS-MIB::scmDiagnosticsDeviceErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.236.11.5.11.64.1.2.1.7.1
snmpget -v2c -c public <target> SAMSUNG-DIAGNOSTICS-MIB::scmDiagnosticsDeviceErrors.1

Start monitoring Samsung SCMI-compliant printers and multifunction devices (MFPs) (diagnostic test execution/results) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SAMSUNG-DIAGNOSTICS-MIB::scmDiagnosticsDeviceErrors OID value, configure state conditions and alerts, and monitor any Samsung SCMI-compliant printers and multifunction devices (MFPs) (diagnostic test execution/results) from a single console.

How to Use in IPNetwork Monitor

Select a Samsung SCMI-compliant printer or multifunction device (MFP) (diagnostic test execution/results) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type scmDiagnosticsDeviceErrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of errors detected on this device. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.236samsungSAMSUNG-COMMON-MIB
1.3.6.1.4.1.236.11divisionSAMSUNG-COMMON-MIB
1.3.6.1.4.1.236.11.5oadivisionSAMSUNG-COMMON-MIB
1.3.6.1.4.1.236.11.5.11samsungCommonMIBSAMSUNG-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.236.11.5.11.64scmDiagnosticsSAMSUNG-DIAGNOSTICS-MIB
1.3.6.1.4.1.236.11.5.11.64.1scmDiagnosticsDeviceSAMSUNG-DIAGNOSTICS-MIB
1.3.6.1.4.1.236.11.5.11.64.1.2scmDiagnosticsDeviceTableSAMSUNG-DIAGNOSTICS-MIB
1.3.6.1.4.1.236.11.5.11.64.1.2.1scmDiagnosticsDeviceEntrySAMSUNG-DIAGNOSTICS-MIB
1.3.6.1.4.1.236.11.5.11.64.1.2.1.7scmDiagnosticsDeviceErrorsSAMSUNG-DIAGNOSTICS-MIB