S5-ETHERNET-MIB :: s5EnPIntconAddrCollect

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › S5-ETHERNET-MIB › s5EnPIntconAddrCollect

s5EnPIntconAddrCollect

Module: S5-ETHERNET-MIB

OID (symbolic): S5-ETHERNET-MIB::s5EnPIntconAddrCollect

OID (numeric): 1.3.6.1.4.1.45.1.6.6.3.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object tells whether the NMM should collect node address information from this port for the Find Nodes and Show Nodes tables.

By default, the node addresses are collected only from ports that are not identified as interconnect ports. This object provides a means of overriding the default for collection and checking of node addresses. The values are: default(1).........follow default rules for address collection neverCollect(2)....don't collect addrs, whatever intercon status alwaysCollect(3)...do collect address, regardless of config

Setting this variable to default(1) tells the NMM to collect and check addresses if and only the port has not been identified as an interconnect port.

To disable node address collection on a port, set this object to neverCollect(2).

To collect node addresses for an interconnect port, set this object to alwaysCollect(3).

To restore the 'natural' value for the port, set this object to default(1).

What is s5EnPIntconAddrCollect?

This read-write object controls whether the NMM collects node address information from a port for the Find Nodes and Show Nodes tables: default(1) follows the normal rule of collecting only from non-interconnect ports, neverCollect(2) disables collection regardless of port type, and alwaysCollect(3) forces collection even on an interconnect port. An admin overrides the default here when they specifically want (or don't want) node-address tracking on a particular port regardless of whether it was auto-identified as an interconnect link. Setting it to neverCollect(2) on a busy uplink port would stop the NMM from tracking individual node addresses seen on that port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.45.1.6.6.3.1.1.5
snmpwalk -v2c -c public <target> S5-ETHERNET-MIB::s5EnPIntconAddrCollect

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.45.1.6.6.3.1.1.5.1
snmpget -v2c -c public <target> S5-ETHERNET-MIB::s5EnPIntconAddrCollect.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.45.1.6.6.3.1.1.5.1 i <value>

Start monitoring Nortel/Bay Networks 5000-series Ethernet switch, BayStack lineage (port interconnection/MAC aging) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the S5-ETHERNET-MIB::s5EnPIntconAddrCollect OID value, configure state conditions and alerts, and monitor any Nortel/Bay Networks 5000-series Ethernet switch, BayStack lineage (port interconnection/MAC aging) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.45synopticsCMU-MIB
1.3.6.1.4.1.45.1productsSYNOPTICS-ROOT-MIB
1.3.6.1.4.1.45.1.6series5000SYNOPTICS-ROOT-MIB
1.3.6.1.4.1.45.1.6.6s5EthS5-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.45.1.6.6.3s5EnMiscS5-ETHERNET-MIB
1.3.6.1.4.1.45.1.6.6.3.1s5EnPIntconTableS5-ETHERNET-MIB
1.3.6.1.4.1.45.1.6.6.3.1.1s5EnPIntconEntryS5-ETHERNET-MIB
1.3.6.1.4.1.45.1.6.6.3.1.1.5s5EnPIntconAddrCollectS5-ETHERNET-MIB