RCV3 :: rc3OperationalMode

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RCV3 › rc3OperationalMode

rc3OperationalMode

Module: RCV3

OID (symbolic): RCV3::rc3OperationalMode

OID (numeric): 1.3.6.1.4.1.1958.1.1.8.3.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The desired state of the Ravlin. For the passall and vpnready modes, the device will act as either a router or a bridge depending on the configuration of the network interfaces. If the two interfaces are on the same network, then the device will function as a bridge, otherwise it will function as a router.

passall - all traffic either in bridge or router mode.

blockall - drop all incoming packets.

vpnready - use the policy database and configuration flags to determine which traffic to pass, block, or apply security.

standby - (READ-ONLY) drop all incoming packets, until the device configuration is not complete. EUse this mode, when the remote interface has DHCP or PPPoE enabled.

What is rc3OperationalMode?

Sets the device's overall traffic-handling posture: passall lets all traffic through (acting as a bridge or router depending on interface configuration), blockall drops every incoming packet, vpnready applies the configured policy database to decide what to pass, block, or secure, and standby (read-only, set automatically) drops all traffic until configuration completes, used while the remote interface waits on DHCP or PPPoE.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1958.1.1.8.3.4
snmpwalk -v2c -c public <target> RCV3::rc3OperationalMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1958.1.1.8.3.4.1
snmpget -v2c -c public <target> RCV3::rc3OperationalMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1958.1.1.8.3.4.1 i <value>

Start monitoring RedCreek Communications VPN/routing gateway (firmware/hardware version and basic IP/interface config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RCV3::rc3OperationalMode OID value, configure state conditions and alerts, and monitor any RedCreek Communications VPN/routing gateway (firmware/hardware version and basic IP/interface config) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1958redCreekRCV3
1.3.6.1.4.1.1958.1productsRCV3
1.3.6.1.4.1.1958.1.1rcRavlinRCV3
1.3.6.1.4.1.1958.1.1.8rcMgmtRCV3
1.3.6.1.4.1.1958.1.1.8.3rc3ControlRCV3
1.3.6.1.4.1.1958.1.1.8.3.4rc3OperationalModeRCV3