RC-POM-MIB :: rcPlugOptModVoltage

MIB Reference — IPNetwork Monitor · Updated September 12, 2026

All MIBsRC-POM-MIBrcPlugOptModVoltage

rcPlugOptModVoltage

Module: RC-POM-MIB

OID (symbolic): RC-POM-MIB::rcPlugOptModVoltage

OID (numeric): 1.3.6.1.4.1.2272.1.71.1.1.22

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: This value represents the internally measured supply voltage. It is a positive number expressed in microvolts and can range from 0 to 65535 mV.

What is rcPlugOptModVoltage?

The transceiver's internally measured supply voltage, expressed in microvolts, which an admin monitors for drift outside the module's normal operating range as a sign of a failing power rail.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2272.1.71.1.1.22
snmpwalk -v2c -c public <target> RC-POM-MIB::rcPlugOptModVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2272.1.71.1.1.22.1
snmpget -v2c -c public <target> RC-POM-MIB::rcPlugOptModVoltage.1

Start monitoring Nortel (Rapid-City-based) switches with DDM-capable pluggable optics (SFP/XFP diagnostic monitoring) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RC-POM-MIB::rcPlugOptModVoltage OID value, configure state conditions and alerts, and monitor any Nortel (Rapid-City-based) switches with DDM-capable pluggable optics (SFP/XFP diagnostic monitoring) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2272rapidCityRAPID-CITY
1.3.6.1.4.1.2272.1rcMgmtRAPID-CITY
1.3.6.1.4.1.2272.1.71rcPlugOptModRAPID-CITY
1.3.6.1.4.1.2272.1.71.1rcPlugOptModTableRAPID-CITY
1.3.6.1.4.1.2272.1.71.1.1rcPlugOptModEntryRAPID-CITY
Numeric OIDNameModule
1.3.6.1.4.1.2272.1.71.1.1.22rcPlugOptModVoltageRC-POM-MIB