RC-BFD-TMP-MIB :: rcBfdTmpSessOperMode

MIB Reference — IPNetwork Monitor · Updated September 12, 2026

All MIBsRC-BFD-TMP-MIBrcBfdTmpSessOperMode

rcBfdTmpSessOperMode

Module: RC-BFD-TMP-MIB

OID (symbolic): RC-BFD-TMP-MIB::rcBfdTmpSessOperMode

OID (numeric): 1.3.6.1.4.1.2272.1.81.1.1.2.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object specifies current operating mode that BFD session is operating in.

A value of AsyncModeWEchoFun(1) ... A value of AsynchModeWOEchoFun(2) ... A value of DemandModeWEchoFunction(3) ... A value of DemandModeWOEchoFunction(4) ...

What is rcBfdTmpSessOperMode?

Reports which of the four BFD operating modes this session is currently running in: asynchronous with or without the Echo function, or demand mode with or without the Echo function; this reflects what was actually negotiated with the peer, not just what was locally requested.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2272.1.81.1.1.2.1.9
snmpwalk -v2c -c public <target> RC-BFD-TMP-MIB::rcBfdTmpSessOperMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2272.1.81.1.1.2.1.9.1
snmpget -v2c -c public <target> RC-BFD-TMP-MIB::rcBfdTmpSessOperMode.1

Start monitoring Nortel Ethernet Routing Switch (pre-standard Bidirectional Forwarding Detection sessions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RC-BFD-TMP-MIB::rcBfdTmpSessOperMode OID value, configure state conditions and alerts, and monitor any Nortel Ethernet Routing Switch (pre-standard Bidirectional Forwarding Detection sessions) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2272rapidCityRAPID-CITY
1.3.6.1.4.1.2272.1rcMgmtRAPID-CITY
1.3.6.1.4.1.2272.1.81rcBfdRAPID-CITY
1.3.6.1.4.1.2272.1.81.1rcBfdTmpMibRAPID-CITY
1.3.6.1.4.1.2272.1.81.1.1rcBfdTmpObjectsRAPID-CITY
1.3.6.1.4.1.2272.1.81.1.1.2rcBfdTmpSessTableRAPID-CITY
1.3.6.1.4.1.2272.1.81.1.1.2.1rcBfdTmpSessEntryRAPID-CITY
Numeric OIDNameModule
1.3.6.1.4.1.2272.1.81.1.1.2.1.9rcBfdTmpSessOperModeRC-BFD-TMP-MIB