RADLAN-RLPFC-MIB :: rlPfcPriorityEnableOperStatusReason

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › RADLAN-RLPFC-MIB › rlPfcPriorityEnableOperStatusReason

rlPfcPriorityEnableOperStatusReason

Module: RADLAN-RLPFC-MIB

OID (symbolic): RADLAN-RLPFC-MIB::rlPfcPriorityEnableOperStatusReason

OID (numeric): 1.3.6.1.4.1.89.148.3.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Reason for priority oper status 'FALSE'.

What is rlPfcPriorityEnableOperStatusReason?

rlPfcPriorityEnableOperStatusReason reports why PFC's operational status for a given 802.1p priority is not active, using named values such as pfcGlobalDis, pfcPriorityAdminDis, sharedQueue, and notSameQueue. Admins consult this object when rlPfcPriorityEnableOperStatus reads false, to diagnose whether the cause is a global PFC disable, a per-priority admin disable, or a queue-mapping conflict where multiple priorities share one hardware queue. For example, a value of sharedQueue(5) tells the admin that PFC failed to activate for that priority because it is mapped to the same egress queue as another priority, so the queue mapping needs to be reconfigured.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.89.148.3.1.4
snmpwalk -v2c -c public <target> RADLAN-RLPFC-MIB::rlPfcPriorityEnableOperStatusReason

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.89.148.3.1.4.1
snmpget -v2c -c public <target> RADLAN-RLPFC-MIB::rlPfcPriorityEnableOperStatusReason.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> rlPfcPriorityEnableOperStatusReason.1

Start monitoring Marvell/RADLAN-based data-center Ethernet switch, OEM DCB-capable switches (802.1Qbb Priority-based Flow Control) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADLAN-RLPFC-MIB::rlPfcPriorityEnableOperStatusReason OID value, configure state conditions and alerts, and monitor any Marvell/RADLAN-based data-center Ethernet switch, OEM DCB-capable switches (802.1Qbb Priority-based Flow Control) from a single console.

How to Use in IPNetwork Monitor

Select a Marvell/RADLAN-based data-center Ethernet switch, OEM DCB-capable switch (802.1Qbb Priority-based Flow Control) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rlPfcPriorityEnableOperStatusReason into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the reason for priority oper status 'FALSE'. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'ok', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.89rndDell-MIB
1.3.6.1.4.1.89.148rlPfcMibDell-MIB
Numeric OIDNameModule
1.3.6.1.4.1.89.148.3rlPfcPriorityTableRADLAN-RLPFC-MIB
1.3.6.1.4.1.89.148.3.1rlPfcPriorityEntryRADLAN-RLPFC-MIB
1.3.6.1.4.1.89.148.3.1.4rlPfcPriorityEnableOperStatusReasonRADLAN-RLPFC-MIB