All MIBs › RADLAN-RLPFC-MIB › rlPfcPriorityEnableOperStatusReason
rlPfcPriorityEnableOperStatusReason
Module: RADLAN-RLPFC-MIB
OID (symbolic): RADLAN-RLPFC-MIB::rlPfcPriorityEnableOperStatusReason
OID (numeric): 1.3.6.1.4.1.89.148.3.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Reason for priority oper status 'FALSE'.
What is rlPfcPriorityEnableOperStatusReason?
rlPfcPriorityEnableOperStatusReason reports why PFC's operational status for a given 802.1p priority is not active, using named values such as pfcGlobalDis, pfcPriorityAdminDis, sharedQueue, and notSameQueue. Admins consult this object when rlPfcPriorityEnableOperStatus reads false, to diagnose whether the cause is a global PFC disable, a per-priority admin disable, or a queue-mapping conflict where multiple priorities share one hardware queue. For example, a value of sharedQueue(5) tells the admin that PFC failed to activate for that priority because it is mapped to the same egress queue as another priority, so the queue mapping needs to be reconfigured.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.89.148.3.1.4 snmpwalk -v2c -c public <target> RADLAN-RLPFC-MIB::rlPfcPriorityEnableOperStatusReason
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.89.148.3.1.4.1 snmpget -v2c -c public <target> RADLAN-RLPFC-MIB::rlPfcPriorityEnableOperStatusReason.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> rlPfcPriorityEnableOperStatusReason.1
Start monitoring Marvell/RADLAN-based data-center Ethernet switch, OEM DCB-capable switches (802.1Qbb Priority-based Flow Control) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADLAN-RLPFC-MIB::rlPfcPriorityEnableOperStatusReason OID value, configure state conditions and alerts, and monitor any Marvell/RADLAN-based data-center Ethernet switch, OEM DCB-capable switches (802.1Qbb Priority-based Flow Control) from a single console.
How to Use in IPNetwork Monitor
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.89 | rnd | Dell-MIB |
| 1.3.6.1.4.1.89.148 | rlPfcMib | Dell-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.89.148.3 | rlPfcPriorityTable | RADLAN-RLPFC-MIB |
| 1.3.6.1.4.1.89.148.3.1 | rlPfcPriorityEntry | RADLAN-RLPFC-MIB |
| 1.3.6.1.4.1.89.148.3.1.4 | rlPfcPriorityEnableOperStatusReason | RADLAN-RLPFC-MIB |