All MIBs › Printer-MIB › prtOutputMinDimXFeedDir
prtOutputMinDimXFeedDir
Module: Printer-MIB
OID (symbolic): Printer-MIB::prtOutputMinDimXFeedDir
OID (numeric): 1.3.6.1.2.1.43.9.2.1.18
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: The minimum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (controlled by prtOutputDimUnit, which uses PrtMediaUnitTC). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown.
NOTE: The above description has been modified from RFC 1759 for clarification and to explain the purpose of (-1) and (-2).
What is prtOutputMinDimXFeedDir?
This value reports (or, on bins without sensing hardware, lets an admin set) the minimum media width an output bin supports, in the units given by prtOutputDimUnit; -1 means other/no restriction, -2 means unknown. It's used alongside the max-width value to define the full range of media sizes a given output bin can accept.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.43.9.2.1.18 snmpwalk -v2c -c public <target> Printer-MIB::prtOutputMinDimXFeedDir
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.43.9.2.1.18.1 snmpget -v2c -c public <target> Printer-MIB::prtOutputMinDimXFeedDir.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.2.1.43.9.2.1.18.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> prtOutputMinDimXFeedDir.1
Start monitoring vendor-neutral, standards-based MIB, network-attached printers and MFPs from any vendor (RFC 3805) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Printer-MIB::prtOutputMinDimXFeedDir OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB, network-attached printers and MFPs from any vendor (RFC 3805) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | AXON-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.43 | printmib | Printer-MIB |
| 1.3.6.1.2.1.43.9 | prtOutput | Printer-MIB |
| 1.3.6.1.2.1.43.9.2 | prtOutputTable | Printer-MIB |
| 1.3.6.1.2.1.43.9.2.1 | prtOutputEntry | Printer-MIB |
| 1.3.6.1.2.1.43.9.2.1.18 | prtOutputMinDimXFeedDir | Printer-MIB |