PRVT-UPS-MIB :: upsConnectedStatus

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PRVT-UPS-MIB › upsConnectedStatus

upsConnectedStatus

Module: PRVT-UPS-MIB

OID (symbolic): PRVT-UPS-MIB::upsConnectedStatus

OID (numeric): 1.3.6.1.4.1.738.1.5.103.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object indicates, if a UPS is connected to the device.

What is upsConnectedStatus?

This reports whether a UPS unit is currently detected as physically connected to this device. Administrators use it as a basic sanity check before relying on any of the other UPS-related monitoring objects, since if no UPS is connected those other readings would be meaningless. A value of disconnected would tell an admin that despite expecting UPS protection, the device currently doesn't see a UPS attached, warranting a cable or connection check.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.5.103.1.1
snmpwalk -v2c -c public <target> PRVT-UPS-MIB::upsConnectedStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.5.103.1.1.1
snmpget -v2c -c public <target> PRVT-UPS-MIB::upsConnectedStatus.1

Start monitoring BATM Advanced Communication switches/ipSwitch platforms with attached UPS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-UPS-MIB::upsConnectedStatus OID value, configure state conditions and alerts, and monitor any BATM Advanced Communication switches/ipSwitch platforms with attached UPS from a single console.

How to Use in IPNetwork Monitor

Select a BATM Advanced Communication switch/ipSwitch platform with an attached UPS as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type upsConnectedStatus into the Find box to locate it in the OID tree, then select it and click OK. This object indicates, if a UPS is connected to the device. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'connected', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1.5.103prvtUPSMibPRVT-UPS-MIB
1.3.6.1.4.1.738.1.5.103.1upsStatusPRVT-UPS-MIB
1.3.6.1.4.1.738.1.5.103.1.1upsConnectedStatusPRVT-UPS-MIB