PRVT-SWITCH-MIB :: reportsHardwareTemperatureHighLimit

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPRVT-SWITCH-MIBreportsHardwareTemperatureHighLimit

reportsHardwareTemperatureHighLimit

Module: PRVT-SWITCH-MIB

OID (symbolic): PRVT-SWITCH-MIB::reportsHardwareTemperatureHighLimit

OID (numeric): 1.3.6.1.4.1.738.1.5.100.3.2.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Displays the highest allowed Celsius (Centigrade) or Fahrenheit temperature at the unit CPU area. When this limit is reached an SNMP notification is sent.

What is reportsHardwareTemperatureHighLimit?

This sets the temperature threshold (20-70 in the selected scale, default 55) at which the switch fires an SNMP notification for exceeding safe operating temperature, letting admins tune how aggressively they're alerted to overheating.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.5.100.3.2.6
snmpwalk -v2c -c public <target> PRVT-SWITCH-MIB::reportsHardwareTemperatureHighLimit

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.5.100.3.2.6.1
snmpget -v2c -c public <target> PRVT-SWITCH-MIB::reportsHardwareTemperatureHighLimit.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.738.1.5.100.3.2.6.1 i <value>

Start monitoring BATM/Telco Systems carrier Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-SWITCH-MIB::reportsHardwareTemperatureHighLimit OID value, configure state conditions and alerts, and monitor any BATM/Telco Systems carrier Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5.100prvtSwitchMibPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5.100.3reportsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5.100.3.2reportsHardwarePRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5.100.3.2.6reportsHardwareTemperatureHighLimitPRVT-SWITCH-MIB