PRVT-CFM-MIB :: prvtCfmMepCcmSequenceErrors

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PRVT-CFM-MIB › prvtCfmMepCcmSequenceErrors

prvtCfmMepCcmSequenceErrors

Module: PRVT-CFM-MIB

OID (symbolic): PRVT-CFM-MIB::prvtCfmMepCcmSequenceErrors

OID (numeric): 1.3.6.1.4.1.738.1.5.131.1.6.1.1.15

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of out-of-sequence CCMs received from all remote MEPs.

What is prvtCfmMepCcmSequenceErrors?

Counts CCM frames received out of sequence from any remote MEP -- a rising counter suggests packet reordering or loss on the monitored path.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.5.131.1.6.1.1.15
snmpwalk -v2c -c public <target> PRVT-CFM-MIB::prvtCfmMepCcmSequenceErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.5.131.1.6.1.1.15.1
snmpget -v2c -c public <target> PRVT-CFM-MIB::prvtCfmMepCcmSequenceErrors.1

Start monitoring BATM carrier Ethernet switches/aggregation nodes with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-CFM-MIB::prvtCfmMepCcmSequenceErrors OID value, configure state conditions and alerts, and monitor any BATM carrier Ethernet switches/aggregation nodes from a single console.

How to Use in IPNetwork Monitor

Select a BATM carrier Ethernet switches/aggregation node as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type prvtCfmMepCcmSequenceErrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of out-of-sequence CCMs received from all remote MEPs. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1.5.131prvtCfmMIBPRVT-CFM-MIB
1.3.6.1.4.1.738.1.5.131.1prvtCfmMIBObjectsPRVT-CFM-MIB
1.3.6.1.4.1.738.1.5.131.1.6prvtCfmMepPRVT-CFM-MIB
1.3.6.1.4.1.738.1.5.131.1.6.1prvtCfmMepTablePRVT-CFM-MIB
1.3.6.1.4.1.738.1.5.131.1.6.1.1prvtCfmMepEntryPRVT-CFM-MIB
1.3.6.1.4.1.738.1.5.131.1.6.1.1.15prvtCfmMepCcmSequenceErrorsPRVT-CFM-MIB