POSEIDON-MIB :: tsAlarmsPresent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › POSEIDON-MIB › tsAlarmsPresent

tsAlarmsPresent

Module: POSEIDON-MIB

OID (symbolic): POSEIDON-MIB::tsAlarmsPresent

OID (numeric): 1.3.6.1.4.1.21796.3.3.50.1

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The present number of active alarm conditions.

What is tsAlarmsPresent?

Reports how many alarm conditions are currently active across the whole device; a nonzero value means you should walk tsAlarmTable to see which sensors or inputs are alarming.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.21796.3.3.50.1
snmpwalk -v2c -c public <target> POSEIDON-MIB::tsAlarmsPresent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.21796.3.3.50.1.1
snmpget -v2c -c public <target> POSEIDON-MIB::tsAlarmsPresent.1

Start monitoring HWg Poseidon environmental monitoring unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the POSEIDON-MIB::tsAlarmsPresent OID value, configure state conditions and alerts, and monitor any HWg Poseidon environmental monitoring unit from a single console.

How to Use in IPNetwork Monitor

Select a HWg Poseidon environmental monitoring unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type tsAlarmsPresent into the Find box to locate it in the OID tree, then select it and click OK. The present number of active alarm conditions. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.21796hwgroupDAMOCLES-MIB
1.3.6.1.4.1.21796.3charonIIDAMOCLES-MIB
Numeric OIDNameModule
1.3.6.1.4.1.21796.3.3poseidonPOSEIDON-MIB
1.3.6.1.4.1.21796.3.3.50tsAlarmPOSEIDON-MIB
1.3.6.1.4.1.21796.3.3.50.1tsAlarmsPresentPOSEIDON-MIB