PM-MIB :: pmPowerMgmtOutletsTablePowerControl

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PM-MIB › pmPowerMgmtOutletsTablePowerControl

pmPowerMgmtOutletsTablePowerControl

Module: PM-MIB

OID (symbolic): PM-MIB::pmPowerMgmtOutletsTablePowerControl

OID (numeric): 1.3.6.1.4.1.10418.17.2.5.5.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. powerLock(5)= when SET the power lock command is sent to PDU. powerUnlock(6)=when SET the power unlock command is sent to PDU. The powerLock and powerUnlock are valid only for Cyclades-PM PDUs

What is pmPowerMgmtOutletsTablePowerControl?

A control object for this one outlet: a GET always returns noAction(1); setting powerOn(2), powerOff(3), powerCycle(4), powerLock(5), or powerUnlock(6) sends that command to just this outlet. This is how an admin remotely power-cycles a single hung server without touching its neighbors; lock/unlock is valid only on Cyclades-PM PDUs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10418.17.2.5.5.1.6
snmpwalk -v2c -c public <target> PM-MIB::pmPowerMgmtOutletsTablePowerControl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10418.17.2.5.5.1.6.1
snmpget -v2c -c public <target> PM-MIB::pmPowerMgmtOutletsTablePowerControl.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10418.17.2.5.5.1.6.1 i <value>

Start monitoring Avocent PM-PDU intelligent power distribution units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PM-MIB::pmPowerMgmtOutletsTablePowerControl OID value, configure state conditions and alerts, and monitor any Avocent PM-PDU intelligent power distribution units from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.10418dellDELLRCSG2-TRAP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10418.17pmPM-MIB
1.3.6.1.4.1.10418.17.2pmManagementPM-MIB
1.3.6.1.4.1.10418.17.2.5pmPowerMgmtPM-MIB
1.3.6.1.4.1.10418.17.2.5.5pmPowerMgmtOutletsTablePM-MIB
1.3.6.1.4.1.10418.17.2.5.5.1pmPowerMgmtOutletsTableEntryPM-MIB
1.3.6.1.4.1.10418.17.2.5.5.1.6pmPowerMgmtOutletsTablePowerControlPM-MIB