PEGASUS-MIB :: perfDataCV

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › PEGASUS-MIB › perfDataCV

perfDataCV

Module: PEGASUS-MIB

OID (symbolic): PEGASUS-MIB::perfDataCV

OID (numeric): 1.3.6.1.4.1.6368.2.7.3.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Number of error checking code faults (the usual error checking code is CRC). DSL links are structured as 166 2/3 frames per second, each with a CRC value. This register is subject to inhibition, that is it counts at most 50 CRC faults per second.

What is perfDataCV?

Count of CRC (code-violation) faults detected in this history register, capped at 50 per second by inhibition rules.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6368.2.7.3.1.6
snmpwalk -v2c -c public <target> PEGASUS-MIB::perfDataCV

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6368.2.7.3.1.6.1
snmpget -v2c -c public <target> PEGASUS-MIB::perfDataCV.1

Start monitoring Schmid Telecom Pegasus SDSL card/rack, DSL access equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PEGASUS-MIB::perfDataCV OID value, configure state conditions and alerts, and monitor any Schmid Telecom Pegasus SDSL card/rack, DSL access equipment from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6368schmidtelecomPEGASUS-MIB
1.3.6.1.4.1.6368.2pegasusMibModulePEGASUS-MIB
1.3.6.1.4.1.6368.2.7perfPEGASUS-MIB
1.3.6.1.4.1.6368.2.7.3perfDataTablePEGASUS-MIB
1.3.6.1.4.1.6368.2.7.3.1perfDataEntryPEGASUS-MIB
1.3.6.1.4.1.6368.2.7.3.1.6perfDataCVPEGASUS-MIB