All MIBs › OPS-MIB › iOpsIADVlSignalFunctionCode
iOpsIADVlSignalFunctionCode
Module: OPS-MIB
OID (symbolic): OPS-MIB::iOpsIADVlSignalFunctionCode
OID (numeric): 1.3.6.1.3.1.1.1.2.2.1.10
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-create
Description: Is the Generic Signal Function code for the voice line. The default value is 'fxsLoopStart'.
What is iOpsIADVlSignalFunctionCode?
This sets the signaling type for the voice line, choosing among FXS variants (fxsLoopStart(1), fxsGroundStart(2), fxsWinkStart(3)), FXO variants (fxoLoopStart(4), fxoGroundStart(5), fxoWinkStart(6)), or E&M variants (eAndM2-2(7), eAndM2-4(8), eAndM4-2(9), eAndM4-4(10)), defaulting to fxsLoopStart. An admin must match this to what the connected phone equipment or PBX trunk expects.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.3 | experimental | APERTUS-NPG-MIB |
| 1.3.6.1.3.1 | clns | CLNS-MIB |
| 1.3.6.1.3.1.1 | clnp | CLNS-MIB |
| 1.3.6.1.3.1.1.1 | clnpForwarding | CLNS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.3.1.1.1.2 | iOpsIADVoiceService | OPS-MIB |
| 1.3.6.1.3.1.1.1.2.2 | iOpsIADVlTable | OPS-MIB |
| 1.3.6.1.3.1.1.1.2.2.1 | iOpsIADVlEntry | OPS-MIB |
| 1.3.6.1.3.1.1.1.2.2.1.10 | iOpsIADVlSignalFunctionCode | OPS-MIB |