ONEACCESS-UPS-MIB :: oacUpsAlarmTime

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ONEACCESS-UPS-MIB › oacUpsAlarmTime

oacUpsAlarmTime

Module: ONEACCESS-UPS-MIB

OID (symbolic): ONEACCESS-UPS-MIB::oacUpsAlarmTime

OID (numeric): 1.3.6.1.4.1.13191.10.3.4.1225.1.2.3

Node type: OBJECT-TYPE

Type: TimeStamp

Access: read-only

Description: The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.

What is oacUpsAlarmTime?

This records the value of the device's uptime counter (sysUpTime) at the moment this particular alarm condition was first detected, giving a timestamp relative to when the agent last started rather than a calendar date. Administrators use it to figure out how long an active alarm has been outstanding, or to correlate it with other logged events around the same uptime value; a value of 0 means the alarm was already present when the agent booted. If sysUpTime was 500 (in hundredths of a second) when a low-battery alarm triggered, this object would record 500, letting an admin calculate the alarm has been active ever since shortly after startup.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.13191.10.3.4.1225.1.2.3
snmpwalk -v2c -c public <target> ONEACCESS-UPS-MIB::oacUpsAlarmTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.13191.10.3.4.1225.1.2.3.1
snmpget -v2c -c public <target> ONEACCESS-UPS-MIB::oacUpsAlarmTime.1

Start monitoring OneAccess CPE router with attached UPS (battery/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ONEACCESS-UPS-MIB::oacUpsAlarmTime OID value, configure state conditions and alerts, and monitor any OneAccess CPE router with attached UPS (battery/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.13191oneAccessONEACCESS-GLOBAL-REG
1.3.6.1.4.1.13191.10oacExperimentalONEACCESS-GLOBAL-REG
1.3.6.1.4.1.13191.10.3oacExpInternalModulesONEACCESS-GLOBAL-REG
1.3.6.1.4.1.13191.10.3.4oacExpIMManagementONEACCESS-GLOBAL-REG
Numeric OIDNameModule
1.3.6.1.4.1.13191.10.3.4.1225oacUpsMIBONEACCESS-UPS-MIB
1.3.6.1.4.1.13191.10.3.4.1225.1oacUpsMIBObjectsONEACCESS-UPS-MIB
1.3.6.1.4.1.13191.10.3.4.1225.1.2oacUpsAlarmONEACCESS-UPS-MIB
1.3.6.1.4.1.13191.10.3.4.1225.1.2.3oacUpsAlarmTimeONEACCESS-UPS-MIB