All MIBs › Nortel-MsCarrier-MscPassport-X25DteMIB › mscX25DteLapbRemoteBusy
mscX25DteLapbRemoteBusy
Module: Nortel-MsCarrier-MscPassport-X25DteMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-X25DteMIB::mscX25DteLapbRemoteBusy
OID (numeric): 1.3.6.1.4.1.562.36.2.1.90.5.13.1.2
Node type: OBJECT-TYPE
Type: Counter32
Access: read-only
Description: This attribute counts the number of times transmission of an I-frame was un-successful due to a perceived remote busy condition (window closed or remote busy).
What is mscX25DteLapbRemoteBusy?
Counts I-frame transmissions that failed because the link perceived the remote end as busy (closed window or remote-busy condition).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.90.5.13.1.2 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-X25DteMIB::mscX25DteLapbRemoteBusy
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.90.5.13.1.2.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-X25DteMIB::mscX25DteLapbRemoteBusy.1
Start monitoring Nortel MainStreet/Passport (MsCarrier Passport) WAN switch (X.25 DTE interfaces) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-X25DteMIB::mscX25DteLapbRemoteBusy OID value, configure state conditions and alerts, and monitor any Nortel MainStreet/Passport (MsCarrier Passport) WAN switch (X.25 DTE interfaces) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.90 | mscX25Dte | Nortel-MsCarrier-MscPassport-X25DteMIB |
| 1.3.6.1.4.1.562.36.2.1.90.5 | mscX25DteLapb | Nortel-MsCarrier-MscPassport-X25DteMIB |
| 1.3.6.1.4.1.562.36.2.1.90.5.13 | mscX25DteLapbStatsTable | Nortel-MsCarrier-MscPassport-X25DteMIB |
| 1.3.6.1.4.1.562.36.2.1.90.5.13.1 | mscX25DteLapbStatsEntry | Nortel-MsCarrier-MscPassport-X25DteMIB |
| 1.3.6.1.4.1.562.36.2.1.90.5.13.1.2 | mscX25DteLapbRemoteBusy | Nortel-MsCarrier-MscPassport-X25DteMIB |