All MIBs › Nortel-MsCarrier-MscPassport-VoiceMIB › mscVsPlcAddressToCall
mscVsPlcAddressToCall
Module: Nortel-MsCarrier-MscPassport-VoiceMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsPlcAddressToCall
OID (numeric): 1.3.6.1.4.1.562.36.2.1.80.3.10.1.20
Node type: OBJECT-TYPE
Type: AsciiString
Access: read-write
Description: This attribute is the PLC's remote end point's address in the format of a NSAP address. As such it must consist of a string of hex digits although not all 40 digits must be specified. For an alternative representation of end point's addresses, see romoteName attribute. If the addressToCall is provisioned, it must match localAddress provisioned on the remote end or the connection will not be established. Connections establish faster and are unique if both ends are provisioned with addressToCall. AddressToCall must be used when the romote end of the connection resides in different topology region. If it resides in the same topology region, then romoteName may be used. When both remoteName and addressToCall are provisioned, addressToCall takes precedence. That is, connection will be established to the service specified by addressToCall.
What is mscVsPlcAddressToCall?
The NSAP-format address (a string of hex digits) of the remote end this path should call, used instead of mscVsPlcRemoteName when the remote end sits in a different topology region; it must match the remote end's localAddress.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.80.3.10.1.20 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsPlcAddressToCall
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.80.3.10.1.20.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsPlcAddressToCall.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.80.3.10.1.20.1 s <value>
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsPlcAddressToCall OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.80 | mscVs | Nortel-MsCarrier-MscPassport-VoiceMIB |
| 1.3.6.1.4.1.562.36.2.1.80.3 | mscVsPlc | Nortel-MsCarrier-MscPassport-VoiceMIB |
| 1.3.6.1.4.1.562.36.2.1.80.3.10 | mscVsPlcProvTable | Nortel-MsCarrier-MscPassport-VoiceMIB |
| 1.3.6.1.4.1.562.36.2.1.80.3.10.1 | mscVsPlcProvEntry | Nortel-MsCarrier-MscPassport-VoiceMIB |
| 1.3.6.1.4.1.562.36.2.1.80.3.10.1.20 | mscVsPlcAddressToCall | Nortel-MsCarrier-MscPassport-VoiceMIB |