All MIBs › Nortel-MsCarrier-MscPassport-VoiceMIB › mscVsFramerTransmitBusyYellow
mscVsFramerTransmitBusyYellow
Module: Nortel-MsCarrier-MscPassport-VoiceMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsFramerTransmitBusyYellow
OID (numeric): 1.3.6.1.4.1.562.36.2.1.80.2.13.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: When this attribute is set to yes and the DS1 or E1 line is set to Channel Associated Signaling (CAS) mode, a 'busy-out' signaling condition is transmitted onto the voice timeslot associated with this Framer when its path across the network is down. The busy-out code transmitted is given by the seizeCode attribute. If transmitBusyYellow is set to yes on a CAS-based interface, seizeCode must be set. When transmitBusyYellow is set to yes and the DS1 or E1 line is set to Common Channel Signaling (CCS) mode, a yellow alarm condition is transmitted onto the DS1/E1 line when the path across the network associated with this Framer is down. Note that in CCS mode, a yellow alarm condition is transmitted when the path is down for any of the Framers with this attribute set to yes.
What is mscVsFramerTransmitBusyYellow?
When set to yes on a CAS-mode DS1/E1 line, transmits a 'busy-out' signal on this Framer's voice timeslot if its path across the network is down; on a CCS-mode line, instead triggers a yellow alarm on the line when the path is down.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.80.2.13.1.1 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsFramerTransmitBusyYellow
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.80.2.13.1.1.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsFramerTransmitBusyYellow.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.80.2.13.1.1.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> mscVsFramerTransmitBusyYellow.1
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsFramerTransmitBusyYellow OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.80 | mscVs | Nortel-MsCarrier-MscPassport-VoiceMIB |
| 1.3.6.1.4.1.562.36.2.1.80.2 | mscVsFramer | Nortel-MsCarrier-MscPassport-VoiceMIB |
| 1.3.6.1.4.1.562.36.2.1.80.2.13 | mscVsFramerSignalTable | Nortel-MsCarrier-MscPassport-VoiceMIB |
| 1.3.6.1.4.1.562.36.2.1.80.2.13.1 | mscVsFramerSignalEntry | Nortel-MsCarrier-MscPassport-VoiceMIB |
| 1.3.6.1.4.1.562.36.2.1.80.2.13.1.1 | mscVsFramerTransmitBusyYellow | Nortel-MsCarrier-MscPassport-VoiceMIB |