Nortel-MsCarrier-MscPassport-VoiceMIB :: mscVsFramerIngressAudioGain

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-VoiceMIB › mscVsFramerIngressAudioGain

mscVsFramerIngressAudioGain

Module: Nortel-MsCarrier-MscPassport-VoiceMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsFramerIngressAudioGain

OID (numeric): 1.3.6.1.4.1.562.36.2.1.80.2.12.1.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies the gain in dB that is applied to data coming from outside the network before it is transferred across the network. It applies to voice, modem and fax traffic. For example, ingress gain is applied to audio data coming from a PBX. If ingressAudioGain is negative, a loss is applied.

If this voice service is running on a DS1V, E1V, 1pDS1V, 1pE1V or J2MV card, ingressAudioGain must be set to 0. If this voice service is running on any other cardtype, ingressAudioGain can be set to any integral value from -12 to +12.

ingressAudioGain and egressAudioGain are used in loss planning, which is the configuration of the devices in the network to ensure that the signal level from any point in the network to any other point is correct.

What is mscVsFramerIngressAudioGain?

The gain (in dB, -12 to +12) applied to audio coming in from outside the network, e.g. from a PBX, before it crosses the network; used together with egressAudioGain for loss planning so signal levels stay correct end to end.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.80.2.12.1.18
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsFramerIngressAudioGain

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.80.2.12.1.18.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsFramerIngressAudioGain.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.80.2.12.1.18.1 i <value>

Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VoiceMIB::mscVsFramerIngressAudioGain OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.80mscVsNortel-MsCarrier-MscPassport-VoiceMIB
1.3.6.1.4.1.562.36.2.1.80.2mscVsFramerNortel-MsCarrier-MscPassport-VoiceMIB
1.3.6.1.4.1.562.36.2.1.80.2.12mscVsFramerCoderTableNortel-MsCarrier-MscPassport-VoiceMIB
1.3.6.1.4.1.562.36.2.1.80.2.12.1mscVsFramerCoderEntryNortel-MsCarrier-MscPassport-VoiceMIB
1.3.6.1.4.1.562.36.2.1.80.2.12.1.18mscVsFramerIngressAudioGainNortel-MsCarrier-MscPassport-VoiceMIB