Nortel-MsCarrier-MscPassport-VncsCallServerMIB :: mscVncsDPDnDestinationNodeId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNortel-MsCarrier-MscPassport-VncsCallServerMIBmscVncsDPDnDestinationNodeId

mscVncsDPDnDestinationNodeId

Module: Nortel-MsCarrier-MscPassport-VncsCallServerMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-VncsCallServerMIB::mscVncsDPDnDestinationNodeId

OID (numeric): 1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.1

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute in conjunction with the destinationComponentId attribute identifies the destination of a voice connection. The destinationNodeId and the destinationComponentId attributes are being replaced by the DataNetworkAddress (Dna) attribute. For the migration procedure consult NTP 241-7001-410 'Passport Voice Networking User Guide'. If the destinationComponentId, the destinationNodeId and the Dna attributes are all set, the call routing is based on the destinationNodeId and the destinationComponentId, unless the call is initiated from the Magellan Passport Access (MPA) module, which will use the Dna attribute. The valid destination call identifier settings are: 1. destinationNodeId and destinationNodeId attributes set 2. destinationNodeId, destinationNodeId and Dna attributes set 3. Dna attribute set For calls initiated from the MPA, only options 2 and 3 are valid.

What is mscVncsDPDnDestinationNodeId?

Together with mscVncsDPDnDestinationComponentId, identifies the destination Passport node of a voice connection for this directory-number entry; this legacy node/component addressing scheme is being replaced by the DataNetworkAddress (Dna) attribute per NTP 241-7001-410. An admin still sets this on older configurations, but calls originated from a Magellan Passport Access (MPA) module will use the Dna attribute instead regardless.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.1
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VncsCallServerMIB::mscVncsDPDnDestinationNodeId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.1.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VncsCallServerMIB::mscVncsDPDnDestinationNodeId.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.1.1 i <value>

Start monitoring Nortel Passport/MSC carrier switching platform (VNCS call server) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VncsCallServerMIB::mscVncsDPDnDestinationNodeId OID value, configure state conditions and alerts, and monitor any Nortel Passport/MSC carrier switching platform (VNCS call server) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.44mscVncsNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2mscVncsDPNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2.2mscVncsDPDnNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2.2.10mscVncsDPDnProvTableNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2.2.10.1mscVncsDPDnProvEntryNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.1mscVncsDPDnDestinationNodeIdNortel-MsCarrier-MscPassport-VncsCallServerMIB