Nortel-MsCarrier-MscPassport-VncsCallServerMIB :: mscVncsDPDnDataNetworkAddress

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNortel-MsCarrier-MscPassport-VncsCallServerMIBmscVncsDPDnDataNetworkAddress

mscVncsDPDnDataNetworkAddress

Module: Nortel-MsCarrier-MscPassport-VncsCallServerMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-VncsCallServerMIB::mscVncsDPDnDataNetworkAddress

OID (numeric): 1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.5

Node type: OBJECT-TYPE

Type: DigitString

Access: read-write

Description: The Dna attribute contains digits which form a unique identifier of the destination of a voice connection. This attribute is used instead of the destinationNodeId and destinationComponentId attributes to identify the destination of the voice connection. This attribute is only used if the destinationNodeId and the destinationComponentId attributes are not set or if the call is initiated from the Magellan Passport Access (MPA) module.

What is mscVncsDPDnDataNetworkAddress?

Holds the digits (up to 15) that make up the DataNetworkAddress (Dna), the modern unique identifier for a voice connection's destination, replacing the older destinationNodeId/destinationComponentId pair. This attribute is used whenever the legacy node/component IDs aren't set, or whenever the call originates from the Magellan Passport Access (MPA) module.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.5
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VncsCallServerMIB::mscVncsDPDnDataNetworkAddress

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.5.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VncsCallServerMIB::mscVncsDPDnDataNetworkAddress.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.5.1 s <value>

Start monitoring Nortel Passport/MSC carrier switching platform (VNCS call server) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VncsCallServerMIB::mscVncsDPDnDataNetworkAddress OID value, configure state conditions and alerts, and monitor any Nortel Passport/MSC carrier switching platform (VNCS call server) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.44mscVncsNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2mscVncsDPNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2.2mscVncsDPDnNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2.2.10mscVncsDPDnProvTableNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2.2.10.1mscVncsDPDnProvEntryNortel-MsCarrier-MscPassport-VncsCallServerMIB
1.3.6.1.4.1.562.36.2.1.44.2.2.10.1.5mscVncsDPDnDataNetworkAddressNortel-MsCarrier-MscPassport-VncsCallServerMIB