All MIBs › Nortel-MsCarrier-MscPassport-VcTesterMIB › mscVctVcfrOoSeqByteCntExceeded
mscVctVcfrOoSeqByteCntExceeded
Module: Nortel-MsCarrier-MscPassport-VcTesterMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcfrOoSeqByteCntExceeded
OID (numeric): 1.3.6.1.4.1.562.36.2.1.5130.5.12.1.10
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: This attribute displays the number times that the out of sequence byte threshold is exceeded. When the threshold is exceeded, this condition is treated as if the loss frame timer has expired and all frames queued at the sink Vc are delivered to the AP. We need to keep this count to examine if the threshold is engineered properly. This should be used in conjunction with the peak value of out-of- sequenced queue and the number of times the loss frame timer has expired. This count should be relatively small when compared with loss frame timer expiry count.
What is mscVctVcfrOoSeqByteCntExceeded?
Counts how many times the out-of-sequence byte threshold was exceeded on this Frame Relay Vc, at which point all queued out-of-sequence frames are delivered as if the loss-frame timer had expired; used to verify the threshold is engineered correctly relative to the frame-loss-timeout count.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.5.12.1.10 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcfrOoSeqByteCntExceeded
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.5.12.1.10.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcfrOoSeqByteCntExceeded.1
Start monitoring Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcfrOoSeqByteCntExceeded OID value, configure state conditions and alerts, and monitor any Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.5130 | mscVct | Nortel-MsCarrier-MscPassport-VcTesterMIB |
| 1.3.6.1.4.1.562.36.2.1.5130.5 | mscVctVcfr | Nortel-MsCarrier-MscPassport-VcTesterMIB |
| 1.3.6.1.4.1.562.36.2.1.5130.5.12 | mscVctVcfrFrdTable | Nortel-MsCarrier-MscPassport-VcTesterMIB |
| 1.3.6.1.4.1.562.36.2.1.5130.5.12.1 | mscVctVcfrFrdEntry | Nortel-MsCarrier-MscPassport-VcTesterMIB |
| 1.3.6.1.4.1.562.36.2.1.5130.5.12.1.10 | mscVctVcfrOoSeqByteCntExceeded | Nortel-MsCarrier-MscPassport-VcTesterMIB |