Nortel-MsCarrier-MscPassport-VcTesterMIB :: mscVctVcfrNotDataXferToSubnet

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-VcTesterMIB › mscVctVcfrNotDataXferToSubnet

mscVctVcfrNotDataXferToSubnet

Module: Nortel-MsCarrier-MscPassport-VcTesterMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcfrNotDataXferToSubnet

OID (numeric): 1.3.6.1.4.1.562.36.2.1.5130.5.12.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This attribute records the number of frames from link discarded when the Vc tries to recover from internal path failure.

What is mscVctVcfrNotDataXferToSubnet?

Counts frames from the link discarded specifically while this Frame Relay Vc was trying to recover from an internal path failure.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.5.12.1.4
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcfrNotDataXferToSubnet

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.5.12.1.4.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcfrNotDataXferToSubnet.1

Start monitoring Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcfrNotDataXferToSubnet OID value, configure state conditions and alerts, and monitor any Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.5130mscVctNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.5mscVctVcfrNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.5.12mscVctVcfrFrdTableNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.5.12.1mscVctVcfrFrdEntryNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.5.12.1.4mscVctVcfrNotDataXferToSubnetNortel-MsCarrier-MscPassport-VcTesterMIB