Nortel-MsCarrier-MscPassport-VcTesterMIB :: mscVctVcOutOfRangeFrmFromSubnet

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-VcTesterMIB › mscVctVcOutOfRangeFrmFromSubnet

mscVctVcOutOfRangeFrmFromSubnet

Module: Nortel-MsCarrier-MscPassport-VcTesterMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcOutOfRangeFrmFromSubnet

OID (numeric): 1.3.6.1.4.1.562.36.2.1.5130.4.12.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This attribute counts the number of subnet frames discarded due to the sequence number being out of range. Two Categories apply for the General Vc 1) lost Acks (previous Range) 2) unexpected Packets (next Range) Vc internally maintains its own sequence number of packet order and sequencing. Due to packet retransmission, Vc may receive duplicate packets that have the same Vc internal sequence number. Only 1 copy is accepted by the Vc and other copies of the same packets are detected through this count. This attribute can be used to record the frequency of packet retransmission due to Vc and other part of the subnet.

What is mscVctVcOutOfRangeFrmFromSubnet?

Counts subnet frames this Vc discarded because their sequence number fell outside the expected range (covering both lost acks and unexpected packets); a rising count signals frequent packet retransmission somewhere in the subnet path.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.4.12.1.2
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcOutOfRangeFrmFromSubnet

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.4.12.1.2.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcOutOfRangeFrmFromSubnet.1

Start monitoring Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctVcOutOfRangeFrmFromSubnet OID value, configure state conditions and alerts, and monitor any Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.5130mscVctNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.4mscVctVcNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.4.12mscVctVcStatsTableNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.4.12.1mscVctVcStatsEntryNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.4.12.1.2mscVctVcOutOfRangeFrmFromSubnetNortel-MsCarrier-MscPassport-VcTesterMIB